0148
REMOVAL
NOTE
Position suitable drain pan under hoses to catch hydraulic fluid.
Tag and mark hoses prior to removal to ensure proper installation.
Cap and plug hoses prior to removal.
Remove cable ties as required.
Perform Steps (1) through (3) to provide clearance for hydraulic reservoir and hoses
removal.
1.
Remove two locknuts (1), cradle (2), U-bolt (3), and bracket (4) from pipe (5).
Discard locknuts.
2.
Remove coupling (6) (WP 0313) and pipe (5) from valve (7).
3.
Remove line (8) from elbow (9).
HWT2029


Back to Top