12. Install washer (40), lockwasher (39), and screw (38) on hydraulic reservoir (31) and bracket (32).
13. Install washer (30), lockwasher (29), and screw (28) on hydraulic reservoir (31) and bracket (32).
14. Install screw (36), two washers (35), lockwasher (34), and nut (33) on hydraulic reservoir (31) and
bracket (37).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
15. Lightly lubricate preformed packing (26) with clean oil, and install preformed packing (26) and hose
1682915 (25) on fitting (27).
16. Lightly lubricate preformed packing (23) with clean oil, and install preformed packing (23) and hose
1682838 (22) on elbow (24).