TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 406 of 1390

TM 9-2320-328-13&P-2
0149-2
DRAFT
0149
INSTALLATION
1.
Install ring (8) on strainer collar (2).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
2.
Apply adhesive on threads of six screws (3).
3.
Install two gaskets (5), strainer (6), and strainer collar (2) on reservoir (7) with six washers (4) and screws (3).
4.
Install breather (1) on strainer collar (2).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Close pump house panel K access door (WP 0008)
2.
Remove wheel chocks (TM 9-2320-422-10)
END OF TASK
END OF WORK PACKAGE
HWT1844
WARNING
ICON 30, 44, 27


Back to Top