TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 389 of 1390

TM 9-2320-328-13&P-2
0146-1
DRAFT
0146
FIELD LEVEL MAINTENANCE
HYDRAULIC RESERVOIR FLUID LEVEL GAUGE REPLACEMENT
INITIAL SETUP:
REMOVAL
Remove fluid level gauge (1) and preformed packing (2) from hydraulic reservoir (3).
Discard preformed packing.
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT2784
Materials/Parts
Fluid, Hydraulic (WP 0400, Item 17)
Preformed Packing (1)
References
WP 0391, Fig. 10
Equipment Conditions
Engine OFF (TM 9-2320-422-10)
Wheels chocked (TM 9-2320-422-10)
Pump house panel K access door opened
(WP 0008)