28. Install wire-routing trim plate (29), two washers (28), lockwashers (27), and screws (26) on pump operator’s
panel housing (30).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
29. Lightly lubricate preformed packing (24) with clean oil, and install preformed packing (24) and hose 1682914
(23) on elbow (25).
30. Lightly lubricate preformed packing (21) with clean oil, and install preformed packing (21) and hose 1682914
(20) on elbow (22).
31. Lightly lubricate preformed packing (18) with clean oil, and install preformed packing (18) and hose 1682914
(17) on elbow (19).