TM-9-2320-328-13-P-3

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 3 OF 3

MARCH 2009

  TM-9-2320-328-13-P-3 - Page 347 of 844

TM 9-2320-328-13&P-3
0377-5
DRAFT
0377
ASSEMBLY
1.
Install fitting (6) on junction box (8) with nut (34).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
2.
Apply sealant to junction box wire harness connector (33).
3.
Install junction box wire harness connector (33) and retainer (32) on junction box (8) with four screws (31).
4.
Install terminal block (16) on junction box (8) with two screws (30).
5.
Install nine wires (29) on terminal block (16) with nine screws (28).
6.
Install four jumpers (27) on terminal block (13).
7.
Install terminal block (13) on junction box (8) with two screws (26).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- -
-
-
-
-
-
-
-
-
-
-
WARNING
ICON 30, 44, 27


Back to Top