TM 9-2320-328-13&P-3
0377-6
DRAFT
0377
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Position solenoid valves, control valve, air regulator, elbows, and fittings as noted prior to
removal.
8.
Apply Teflon tape to threads of seven elbows (3), two tee fittings (5), and fittings (4).
9.
Install tee (25), elbow (24), control valve (23), and two tees (5) on air regulator (22).
10. Install two fittings (4) and seven elbows (3) on four solenoid valves (18) and air regulator (22).
11. Install air regulator (22) on air regulator bracket (20) with nut (21).
12. Install regulator bracket (20) on junction box (8) with two screws (19).
13. Install four solenoid valves (18) on junction box (8) with eight screws (17).