11. Install windshield deluge shutoff valve (12), strainer (13), and hose (11) on windshield deluge motor (10) and
secure retainer clip (9).
12. Install bulkhead fitting (7) on bracket (8) and tighten lockwasher (6) and nut (5).
13. Install hose (3) on elbow (4).
14. Connect windshield deluge motor connector (1) on pump house connector (2).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Install bumper turret valve (WP 0312)
2.
Connect batteries (TM 9-2320-325-14&P)
END OF TASK
END OF WORK PACKAGE