FIELD LEVEL MAINTENANCE
PNEUMATIC SPRING REPLACEMENT
INITIAL SETUP:
REMOVAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Pneumatic springs must be replaced when module doors start to drift down when in
open position or when they are no longer able to push up on module door when
opening.
Failure to comply may result in injury to personnel or damage to
equipment.
Do not allow pump house access door to drop.
Pump house access doors are
heavy and can cause injury to personnel or damage to equipment.
NOTE
Note position of pneumatic spring prior to removal to ensure proper installation.
Both pneumatic springs and are replaced the same way.
Rear pneumatic spring shown.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
WARNING
ICON 8, 10
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Locknut (2)
Lockwasher (2)
Personnel Required
MOS 63B Wheeled Vehicle Mechanic (2)
References
WP 0391, Fig. 72
Equipment Conditions
Engine OFF (TM 9-2320-422-10)
Wheels chocked (TM 9-2320-325-14&P)
Hose reel cover opened (WP 0009)