TM 9-2320-361-34
17-4. ENGINE COOLANT HEATER RESTRICTION THERMOSTAT MAINTENANCE
THIS TASK COVERS:
a. Removal
c. Installation
b. Inspection
INITIAL SETUP
APPLICABLE MODELS
REFERENCES (TM)
All
TM 9-2320-361-34P
TEST EQUIPMENT
EQUIPMENT CONDITION
Multimeter (Appendix B, Item 3)
Engine coolant heater blower motor removed
(para. 17-3).
TOOLS
General mechanic’s tool kit
(Appendix B, Item 1)
Tool kit, electrical (Appendix B, Item 2)
a. Removal
NOTE
Tag wires for installation.
1. Disconnect
two leads (1) from restriction thermostat (3).
2.
Remove two nut-assembled lockwashers (2), restriction thermostat (3), and two spacers (4) from two
studs (5).
b. Inspection
1. Inspect restriction thermostat (3) for corrosion and bends. Replace if corroded or bent.
2.
Check thermostat continuity at room temperature. If continuity exists, replace thermostat (3).
CAUTION
Do not place thermostat m liquid for cooling. Placing thermostat
in liquid will cause damage to equipment.
3.
Cool thermostat to 20F (-6.7°C). Check thermostat continuity. If continuity does not exist, replace
thermostat.
I
c. Installation
1. Install restriction thermostat (3) and two spacers (4) on two studs (5) with two nut-assembled
lockwashers (2).
2. Connect two leads (1) to restriction thermostat (3).
17-8