4-18. EES KIT INSTALLATION (Cont’d)
q. Water Pump Pulley Installation
1.
Clean threads of four sockethead screws (1) retained from removal
of water pump pulley (TM 9-2320-280-20).
2.
Install water pump pulley (2) on water pump (3).
3.
Apply sealing compound to four sockethead screws (1).
4
0
Secure water pump pulley (2) to water pump (3) with four
sockethead screws (1).
5.
Using 6mm hex socket wrench attachment, tighten sockethead
screws (1) to 180-240 lb-in. (20-27 N
m).
4-58