TM-9-2320-366-34-3

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE; VOLUME NO. 3 OF 4

AUGUST 2005
CHANGE 2

  TM-9-2320-366-34-3 - Page 577 of 1178

TM 9-2320-366-34-3
WARNING
Adhesive
Sealant
MIL-S-46163
can
damage your eyes. Wear safety goggles
when using; avoid contact with eyes. If
sealant contacts eyes, flush eyes with
water
and
get
immediate
medical
attention. Failure to comply may result in
injury to personnel.
(4) Apply sealing compound to threads of screws (8).
(5) Install manual override valve (7) and valve bracket (9)
on
control panel (10) with two screws (8), four
washers (11) two lockwashers (12), and two nuts (13).
(6) Connect hydraulic hoses (14 and 15) to manual override
valve (7).
(7) Connect electrical connector O (16) to manual override
valve (7).
c. Follow-On Maintenance.
(1) Place hydraulic reservoir supply valve and return valve
in open position (TM 9-2320-366-10-2).
(2) Connect batteries (TM 9-2320-366-20-3).
(3) Operate MHC and check for hydraulic leaks at manual
override valve (TM 9-2320-366-10-2).
End of Task.
16-341