TM-9-2320-366-34-3

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE; VOLUME NO. 3 OF 4

AUGUST 2005
CHANGE 2

  TM-9-2320-366-34-3 - Page 579 of 1178

TM 9-2320-366-34-3
All data on page 16-344 deleted
Change 2
16-343
a. Static Overload Test.
(1)
Extend boom (1) to 15 feet, 0 inches.
(2)
Raise boom (1) approximately 25
for a load
radius of 11 feet, 0 inches.
(3)
Lower crane hook (2) with hoist (3).
(4)
Connect 12100 lb test weight (4) to hook (2).
(5)
Attempt to raise test weight (4) with hoist (3).
(6)
Place crane power switch (5) to OFF.
(7)
Depress manual override (6).
(8)
Raise test weight (4) approximately six inches with
hoist (3).
(9)
Release manual override (6).
(10) Depress manual override (6).
(11) Lower test weight (4) to ground with hoist (3).
(12) Release manual override (6).
(13) Disconnect 12100 lb test weight (4) from hook (2).
NOTE
Static overload test is performed with a test
load of 110% of crane rated load on Range
Diagram for this boom extension and
radius.
The overload protection system
should prevent lifting of this test weight.
NOTE
If test weight is lifted refer to troubleshooting
to determine failure of overload protection
system.
NOTE
Hold manual override depressed until test
weight is raised.
NOTE
Test weight will remain suspended.


Back to Top