TM-9-2320-440-13-P

TERMINAL HIGH ALTITUDE AREA DEFENSE (THAAD) CARRIER

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

AUGUST 2010

  TM-9-2320-440-13-P - Page 264 of 1616

TM 9-2320-440-13&P
0029-2
0029
LHS AND MRP DO NOT OPERATE (CONTINUED)
THAAD0547
NOTE
Each VIM has two HEART BEAT indicator lights. One HEART BEAT indicator light will
steadily illuminate steady and the second HEAT BEAT indicator will flash, when the VIM is
operating correctly.
Step 2.
Check if one HEART BEAT indicator light is illuminated and the second HEART BEAT
indicator light is flashing on both VIMs.
If the HEART BEAT indicator lights are not illuminated as indicated on both
VIMs, troubleshoot LHS Cab Control Fails Self Test or No VIM Heart Beat
Indication (WP 0030).
Step 3.
Position LHS cab control mode select switch to MRP position (WP 0012). Check if LHS
cab control LHS ENGAGED indicator light illuminates.
If LHS cab control LHS ENGAGED indicator light does not illuminate,
troubleshoot LHS ENGAGED Indicator Light Does Not Operate (WP 0022).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top