TM 9-2320-440-13&P
0037-4
0037
MRP DOES NOT EXTEND (CONTINUED)
THAAD0627
NOTE
Elevation cylinders may not extend at same rate before they engage MRP. Once first
elevation cylinder engages MRP, second elevation cylinder should extend until it engages
MRP.
Then both elevation cylinders should extend at same rate.
Step 6.
Operate elevation cylinder controls (WP 0007). Check if at least one elevation cylinder
extends when MRP elevation controls are operated (WP 0007). Shut off
engine (
a.
If both cylinders extend when operating MRP, problem is corrected.
b.
If only one elevation cylinder extends, replace nonoperating cylinder
(WP 0139).
c.
If both elevation cylinders do not extend, replace MRP distribution
manifold (WP 0126).
THAAD0628
Step 7.
Remove safety wire from solenoid HV9. Soldier A check for 3,000 psi (20,684 kPa) at
test port TP5, while HV9 bypass valve is pulled out and turned while Soldier B attempts
to extend MRP elevation cylinders (WP 0007). Shut off engine (
If 3,000 psi (20,684 kPa) is not measured, install safety wire on solenoid HV9
and replace MRP control valve (WP 0138).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION