TM 9-2320-440-13&P
0040-2
0040
MRP LOCKS DO NOT ENGAGE (CONTINUED)
THAAD0634
Step 2.
Inspect hydraulic hoses 2740 and 2741, tubing, and fittings from MRP control valves to
left and right rack locks for leaks, kinks, and damage (See WP 0119).
If hydraulic hoses, tubes and/or fittings leak, or are damaged, tighten loose
fittings or replace damaged tubes and hoses (WP 0119).
THAAD0635
NOTE
MRP present proximity switches must be active to engage MRP rack locks.
If MRP rack
is not loaded, activate both MRP present proximity switches by placing a metal object
over proximity switches while engaging MRP rack locks.
Step 3.
If MRP is not loaded, place metal objects over MRP present proximity switches. Then
start engine (
and operate MRP rack locks (WP 0012). Check if
MRP rack locks engage (WP 0012). Shut off engine (
a.
If one rack lock cylinder does not engage, replace nonoperating cylinder
(WP 0140).
b.
If both rack lock cylinders do not engage, go to Step 4.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TM 9-2320-347-10)
TM 9-2320-347-10)