MRP LOCKS DO NOT ENGAGE (CONTINUED)
THAAD0623A
WARNING
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment or
severe burns or electrical shock to personnel.
NOTE
Perform Step 9 if no vdc is present on wire 1976A at connector REC10, terminal 9 in
Step 7.
Perform Step 10 if no vdc is present on wire 1976B at connector REC10, terminal 9 in
Step 7.
Step 9.
Disconnect THAAD control valve harness VIM No. 1, 24 pin connector (WP 0089).
Check for continuity across wire 1976A from VIM No. 1, 24 pin connector, terminal 9 to
connector REC10, terminal 2.
a.
If there is continuity, replace VIM No. 1 (WP 0089).
b.
If there is no continuity, repair wire 1976A (TM 9-2320-325-14&P) or
replace THAAD control valve harness (WP 0088).