TM 9-2320-440-13&P
0040-7
0040
MRP LOCKS DO NOT ENGAGE (CONTINUED)
THAAD0623A
Step 10.
Disconnect THAAD control valve harness VIM No. 2, 24 pin connector (WP 0089).
Check for continuity across wire 1976B from VIM No. 2, 24 pin connector, terminal 9 to
connector REC10, terminal 3.
a.
If there is continuity, replace VIM No. 2 (WP 0089).
b.
If there is no continuity, repair wire 1976B (TM 9-2320-325-14&P) or
replace THAAD control valve harness (WP 0088).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top