TM 9-2320-440-13&P
0051-5
0051
WARNING
SOLVENT CLEANING COMPOUND
Solvent cleaning compound MIL-PRF-680 Type II and III may be irritating to the eyes
and skin. Use protective gloves and goggles. Use in well-ventilated areas. Use
respirator as needed. Accidental ingestion can cause irritation of digestive tract
and respiratory tract, may cause lung and central nervous system damage. Can be
fatal if swallowed. Inhalation of high/massive concentrations can cause coma or be
fatal. First aid for ingestion: do not induce vomiting. Seek immediate medical
attention. First aid for skin contact: remove contaminated clothing. Wash skin
thoroughly with soap and water. If symptoms persist, seek medical attention. First
aid for eye contact: flush with water for 15 minutes or until irritation subsides. If
symptoms persist, seek medical attention. First aid for inhalation: move to fresh air.
If not breathing, provide artificial respiration. If symptoms persist, seek medical
attention. Keep away from open flames and other sources of ignition. Failure to
follow this warning may result in injury or death to personnel.
•
The flashpoint for type II solvent cleaning compound is 141-198ºF (61-92ºC)
and type III is 200-241ºF (93-116ºC).
•
Improper cleaning methods and use of unauthorized cleaning solvents may
injure personnel and damage equipment
•
Fire extinguishers should be placed nearby when using solvent cleaning
compound. Failure to follow this warning may result in injury or death.
•
Cloths or rags saturated with solvent cleaning compound must be disposed of
IAW authorized facilities’ procedures. Failure to follow this warning may result
in injury.
•
Eye shields must be worn when cleaning with a wire brush. Flying rust and
metal particle may cause injury.
•
Never use fuel to clean parts. Fuel is highly flammable. Serious personal injury
could result if fuel ignites during cleaning.
i.
Passages.
After degreasing, check all oil passages and cavities for dirt or blockage before coating with
lubricating oil (WP 0186, Item 25). Run a thin, flexible wire through oil passages to make sure they are not
clogged. Use a pressure spray gun and solvent cleaning compound (WP 0186, Item 7) to clean dirty
passages.
j.
Electrical Parts.
Electrical parts; such as coils, junction blocks, and switches, should not be soaked or
sprayed with cleaning solutions. Clean these parts with a cleaning cloth (WP 0186, Item 8) moistened with
solvent cleaning compound (WP 0186, Item 7).
k.
Hydraulic System.
When cleaning hydraulic system parts, use solvent cleaning compound (WP 0186,
Item 7). Clean and dry parts thoroughly to make sure no residue remains. If a coating preservative is required
before assembly, apply a light film of lubricating oil (WP 0186, Item 25). If petroleum-free solvents are not
available, use the same hydraulic fluid as used in vehicles system.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- -
-
-
-
-
-
-
-
-
-
-