TM-9-2320-440-13-P

TERMINAL HIGH ALTITUDE AREA DEFENSE (THAAD) CARRIER

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

AUGUST 2010

  TM-9-2320-440-13-P - Page 512 of 1616

TM 9-2320-440-13&P
0052-2
0052
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3.
Install 0-6000 psi (0-41,370 kPa) pressure gage (8) on test port (7).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Hydraulic oil in reservoir must be 105°F ± 5°F (41°C ± 2°C) to obtain proper pressure
reading.
Engine must be at full throttle to obtain proper pressure reading.
4.
Soldier A, start engine (
engage PTO (
turn hydraulic selector
switch (9) to MAN HOOK ARM position, and move joystick (10) to LOAD. Soldier B, record pressure reading.
5.
Shut off engine (
THAAD0555
THAAD0556
TM 9-2320-347-10)
TM 9-2320-347-1
TM 9-2320-347-10)


Back to Top