3.
Apply soap solution to edge of lamp (4).
4.
Pry off edge of work light (2) from lamp (4).
5.
Loosen two screws (5) and remove switch power wire (6) and ground wire (7) from lamp (4).
6.
Remove splice cap (8) from internal power wire (9).
7.
Remove retainer nut (10) and switch (11) from work light (2).
END OF TASK
INSTALLATION
1.
Install switch (11) on work light (2) with retainer nut (10).
2.
Install splice cap (8) on internal power wire (9).
3.
Install ground wire (7) and switch power wire (6) on lamp (4) and tighten two screws (5).
4.
Install lamp (4) in work light (2).