TM 9-2320-440-13&P
0105-2
0105
-
-
-
-
- .Outrigger pads may have sharp edges. Use care when removing
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
WARNING
Keep hands and feet clear of outriggers during outrigger/stabilizer extension and
retraction. Failure to comply may result in injury or death to personnel.
NOTE
•
Left and right stabilizer (STABILIZER LH and STABILIZER RH) control levers can be
operated independently or at the same time.
•
Stabilizer movement from one lever may be slower than the other when operating two
levers together.
•
Air suspension will automatically deflate when outriggers are deployed.
7.
Push and hold palm button switch (6).
8.
Move OUTRIGGER LH control lever (7) and OUTRIGGER RH control lever (8) to deploy outrigger
approximately 6-10 inches (15.24-25.40 cm).
9.
Move STABILIZER LH control lever (9) and STABILIZER RH control lever (10) to DOWN position to lower
outrigger stabilizer cylinder rods. Deploy stabilizers approximately 10 in. (25.40 cm).
10. Release palm button switch (6).
11.
.Turn hydraulic selector switch (5) to OFF position.
12. Move PTO ENGAGED switch (3) to OFF position. Indicator light (4) should extinguish.
13. Shut off engine (
THAAD0314
TM 9-2320-347-10)