TM 9-2330-335-14&P
0094-2
0094
OPERATION OF HOLLAND FORMULA 150 LANDING GEAR - CONTINUED
Retract
00094
1.
On outside-mounted landing gear, engage crank with crankshaft and turn the crank counterclockwise. Inside-
mounted landing gear are retracted by turning the crank clockwise. Retract the landing gear using low gear until
unloaded. Then shift to high gear and continue cranking until fully retracted. Leave the crankshaft engaged to
prevent road vibration wind-down. Store the crank in the holder provided.
2.
Before operating, identify the mounting style of your landing gear, inside or outside mount (see Figures 1 and 2).
Figure 1.
Outside Mount.
094
a.
Push crank handle in for low speed.
b.
Pull crank handle out for high speed.
c.
Turn crank:
(1) Counterclockwise = extend
(2) Clockwise = retract
447-0103