PREPARATION FOR USE - CONTINUED
4.
Connecting Intervehicular Cable.
CAUTION
The semitrailer’s convertor box and electrical system will be damaged if the 12V (7 pin) and 24V
(12 pin) cables are plugged in at the same time. Do not plug both the 12V (7 pin) and 24V (12 pin)
cables in at the same time. Failure to comply may result in equipment damage.
a.
Open the cover on the receptacle (Figure 4, Item 1 or 2).
b.
Align slot on cable plug with aligning key of receptacle (Figure 4, Item 1 or 2).
c.
Push cable plug into matching receptacle (Figure 4, Items 1 or 2) and release receptacle cover.
d.
Operate lights from towing vehicle to make certain lights are in working order.
e.
Check the air lines and intervehicular cable to ensure they are supported and will not catch or chafe.
f.
Recheck fifth wheel to kingpin locking by trying to move towing vehicle and semitrailer forward.
Figure 4.
Cables.
05
447-0196
M871R
M871A1R and M871A2R