INSTALLATION - Continued
7
1
2
3
4
5
6
Figure 6.
Air Reservoir No. 1 Installation.
2.
Install fitting (Figure 6, Item 5) in air reservoir (Figure 6, Item 3).
3.
Apply sealing compound on threads of fitting (Figure 6, Item 6).
4.
Install fitting (Figure 6, Item 6) on fitting (Figure 6, Item 5).
5.
Apply sealing compound on threads of fitting (Figure 6, Item 4).
6.
Install fitting (Figure 6, Item 4) on fitting (Figure 6, Item 5).
7.
Install cable (Figure 6, Item 2) on air reservoir bracket (Figure 6, Item 7).
8.
Apply sealing compound on threads of drain valve (Figure 6, Item 1).
9.
Install drain valve (Figure 6, Item 1) on air reservoir (Figure 6, Item 3).
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open flame and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
CAUTION
Use sealing compound sparingly and only on threads. Do not apply compound on hose
connections. Damage to equipment may result.
10.
Apply sealing compound on threads of fitting (Figure 7, Item 2).
TM 9-2330-342-23&P
0068
0068-5