REMOVAL - Continued
NOTE
The relief valve is marked with an arrow to show proper direction during installation. Note
direction of arrow, or if arrow is missing, or obscured, mark relief valve to aid in installation.
2.
Remove air lines 2231 (Figure 1, Item 3) and 2232 (Figure 1, Item 1) from fittings (Figure 1, Item 5) and (Figure
1, Item 2).
3.
Remove fitting (Figure 2, Item 1) from valve (Figure 2, Item 2).
2
1
3
Figure 2.
Relief Valve Removal.
4.
Remove fitting (Figure 2, Item 3) from valve (Figure 2, Item 2).
END OF TASK
INSTALLATION
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open flame and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
CAUTION
Use sealing compound sparingly and only on threads. Do not apply compound on hose
connections. Damage to equipment may result.
NOTE
Install cable ties as required.
1.
Apply sealing compound on threads of fitting (Figure 3, Item 3).
TM 9-2330-342-23&P
0088
0088-2