TM 9-2350-238-20-1
2-192. MAINTENANCE OF OIL RESERVOIR HEATER KIT AND ELECTRICAL WIRING
(CONT).
INSTALLATION (CONT)
4
Install angle bracket (6), two machine bolts (7), two new lockwashers (8), and two hexagon
plain nuts (9).
5
Install spring tension clip (10) and assembled washer screw (11) on angle bracket (6).
6
Install shell connector of relay and disconnect to slave receptacle special cable assembly (4) in
spring tension clip (10).
7
Install immersion heater relay and housing (12), two new lockwashers (13), and two hexagon
head capscrews (14).
8
Install overheat thermostat to relay branched wiring harness (15). Untag and connect shell
connector to relay and disconnect to slave receptacle special cable assembly (4) at line
connection.
9
Install relay to heating element electrical lead (16). Untag and connect plug connectors of
overheat thermostat to relay branched wiring harness (15), relay to heating element electrical
lead, and relay and disconnect to slave receptacle special cable assembly (4) to immersion
heater relay and housing (12).
2-1092