TM 9-2350-238-20-1
2-137. MAINTENANCE OF HYDRAULIC POWER SUPPLY LINES AND FITTINGS (AFT
SECTION).
This task covers:
a.
Removal
b.
hspection/Repair
c.
lnstallation
INITIAL SETUP
Materials/Parts
Locknut
Locknut
Lockwasher (6)
Preformed packing (2)
Preformed packing (5)
References
TM 9-2350-238-24P-1
General Safety Instructions
•
To avoid injury to personnel, do not tighten or loosen hydraulic fittings when
system is pressurized.
•
Lower the boom to stowed position before doing any maintenance on hydraulic
system.
. Wipe up any spilled hydraulic fluid to prevent injury to personnel.
REMOVAL
•
•
•
To avoid injury to personnel, do not tighten or loosen hydraulic fittings when system
is pressurized.
Lower the boom to stowed position before doing any maintenance on hydraulic
system.
Wipe up any spilled hydraulic fluid to prevent injury to personnel.
Install covers on open hydraulic ports, tubes, and hoses immediately after disconnect-
ing them to keep dirt out of hydraulic system.
NOTE
Access to aft hydraulic power supply fittings is gained through the cab well.
2-797