TM 9-2350-238-20-1
INSTALLATION
1
2
3
4
5
6
7
8
9
10
Install new locknut (1) on tee (2).
Install new preformed packing (3) and new preformed packing (4) on tube reducer (5).
Install tube reducer (5) with attached packings on tee (2).
Install new locknut (6), packing retainer (7), and new preformed packing (8) on tube tee (9).
Install tube tee (9) with attached parts in hull.
Install safety relief valve (10) on tube reducer (5) and tube tee (9), and tighten locknut (6) on
tube tee.
Install new preformed packing (11) on tube nipple (12).
Install tube nipple (12) with preformed packing (11) on slip ring and pump assembly (13).
Connect tee to pump metal tube assembly (14) to tube nipple (12).
Connect tee to pump metal tube assembly (14) to tee (2), and tighten locknut (1) on tee.
2-801