TM 9-2350-238-34-1
2-50. MAINTENANCE OF AIR CLEANER ACCESS DOOR (CONT) .
1
2
3
Inspect for broken, damaged, or missing parts.
If air cleaner door is broken, damaged, or missing, repair is by replacement of next higher
assembly .
Repair is by replacement of authorized parts (TM 9-2350-238-24P-1) which do not meet inspection
criteria.
.
1
2
3
4
5
If nonmetallic seal (1) was removed, clean
air cleaner door (2) with cleaning compound.
Coat new nonmetallic seal (1) with adhesive,
and install on air cleaner door (2).
Install rim latch (3) on air cleaner door (2),
and secure with four new Iockwashers (4)
and four machine screws (5).
Install manual control handle (6) and new
spring pin (7) on headed straight pin (8).
Install new spring tension washer (9), flat
washer (10), and headed straight pin (8) with
manual control handle (6) on air cleaner
door (2).
Install new spring tension washer (11), flat
washer (12), and new spring pin (13) on
headed straight pin (8).
2-15 4