TM 9-2350-238-34-2
2-44. MAINTENANCE OF SOLENOID VALVE (CONT).
HIGH-PRESSURE SETTING ADJUSTMENT (CONT)
5 Install 3000 psi (20,685 kpa) oil pres
sure tester in test port (4).
6 Pull out TRAVERSING BRAKE PRESSURE
SELECTOR knob (5) to prevent hydraulic
system pressure from releasing travers-
ing brakes.
7 Set LEVEL WIND switch (6) to ON.
OIL
PRESSURE
TESTER
2-212