TM 9-2350-238-34-2
2-44. MAINTENANCE OF SOLENOID VALVE (CONT).
HIGH-PRESSURE
SETTING ADJUSTMENT (CONT)
12
13
14
15
16
17
18
Do not allow pressure to go over
1850 psi {12,756 kPa). Failure to
follow instructions may result in
damage to equipment.
Adjust pressure for solenoid valve (3) to
between 1650 and 1850 psi (11,377
and 12,756 kPa) by turning screw (9)
counterclockwise to decrease pressure or
clockwise to increase pressure.
When correct pressure adjustment is ob-
tained, tighten nut (8).
If correct pressure adjustment cannot be
obtained, replace solenoid valve (3).
Refer to page 2-192.
Turn off hydraulic system. Refer to TM
9-2350-238-10.
Set LEVEL WIND switch (6) to OFF.
Release level wind assembly. Refer to
TM 9-2350-238-10.
OI L
PRESSURE
TESTER
Push in TRAVERSING BRAKE PRESSURE
SELECTOR knob (5).
2-214