TM-9-2350-256-10

RECOVERY VEHICLE, FULL TRACKED: MEDIUM, M88A1

OPERATOR'S MANUAL

OCTOBER 2014

  TM-9-2350-256-10 - Page 293 of 796

ACETYLENE/OXYGEN HOSES INSTALLATION
1.
Check hoses for burns, knicks, and damaged fittings.
NOTE
Acetylene hose connection has left-hand threads.
2.
Connect red hose to acetylene regulator and green hose to oxygen regulator. Screw connecting nuts
(Figure 3, Item 1) tightly to ensure leak-proof seating.
WARNING
Acetylene gas is extremely flammable and stored under high pressure. Ensure
cylinder is properly stowed and connected. Damage to cylinder or leaking lines
could cause an explosion. Failure to comply may result in personnel death, injury,
and/or damage to equipment.
Always blow out acetylene hose in well-ventilated areas, away from heat, sparks,
and flames. Use eye protection or face shield and protective gloves. Do not
breathe fumes. Continued exposure can cause dizziness and irritate your eyes and
throat. Failure to comply may result in personnel death or injury.
3.
Release both regulator screws (Figure 3, Item 2) to avoid damage to regulators and gauges.
Figure 3.
Regulator Screw.
TM 9-2350-256-10
0053
0053-3