DISCONNECTING EXOTHERMIC CUTTER - Continued
5.
Close oxygen cylinder valve (Figure 11, Item 4).
6.
Set regulator valve (Figure 11, Item 1) to 0 psi.
7.
Disconnect oxygen hose (Figure 11, Item 2) from regulator valve (Figure 11, Item 1) and exothermic cutter
(Figure 11, Item 3).
Figure 11.
Oxygen Cylinder and Exothermic Cutter.
END OF TASK
TM 9-2350-256-10
0052
0052-16