AUXILIARY POWER UNIT (APU) FAILS TO START - Continued
CORRECTIVE ACTION - Continued
2.
Place APU GEN switch as necessary.
3.
Start APU (WP 0042).
4.
If APU fails to start, proceed to next malfunction.
MALFUNCTION
Fuel level is low.
CORRECTIVE ACTION
1.
Check fuel level.
WARNING
•
Fuel is very flammable and can explode easily.
When working with fuel, post signs that read: "NO SMOKING WITHIN
50 FEET OF VEHICLE."
Keep fuel away from open flame or extreme heat.
Always keep fire extinguisher within easy reach when working with fuel.
Failure to comply may result in personnel death or injury.
•
Fuel is slippery and may cause falls. Wipe up spillage immediately with
rags. Dispose of materials in accordance with local hazardous waste
disposal procedures. Failure to comply may result in personnel death,
injury, and/or damage to equipment.
NOTE
Check mechanic side rear tank fuel level. Fuel tank level needs to be above a
quarter tank full. Refer to Preventive Maintenance Checks and Services
(PMCS) – After, Including Lubrication Instructions (WP 0098).
2.
Fuel vehicle (WP 0117) if necessary.
3.
Attempt to start APU (WP 0042).
4.
If APU fails to start, proceed to next malfunction.
MALFUNCTION
Low battery charge.
CORRECTIVE ACTION
1.
Check for low battery charge indicated on BATT-GEN gauge.
TM 9-2350-256-10
0083
0083-2