APU STARTS BUT FAILS TO KEEP RUNNING OR RUNS ROUGHLY - Continued
MALFUNCTION
Air intake restriction.
CORRECTIVE ACTION
1.
Check air intake for restrictions.
2.
Remove restrictions or clean air filter (WP 0120).
3.
Start APU (WP 0042) and check operation.
4.
If APU fails to keep running, notify maintenance.
BATT-GEN GAUGE READS IN YELLOW OR LOWER RED WITH APU RUNNING AND APU GEN SWITCH ON
SYMPTOM
BATT-GEN gauge reads in yellow or lower red with APU running and APU GEN switch on.
MALFUNCTION
SYSTEM SELECT lever is in wrong position.
CORRECTIVE ACTION
1.
Place SYSTEM SELECT lever in MAIN position.
2.
Start APU (WP 0042) and check BATT-GEN gauge reading.
3.
If BATT-GEN gauge continues to read in yellow or lower red with APU running and APU GEN
switch on, proceed to next malfunction.
MALFUNCTION
Voltage regulator needs resetting.
CORRECTIVE ACTION
1.
Open air intake grilles (WP 0030) above voltage regulator.
2.
Start APU (WP 0042) and check BATT-GEN gauge reading.
3.
Press RESET button on voltage regulator (WP 0118).
4.
Check if BATT-GEN gauge continues to read in yellow or lower red with APU running and APU
GEN switch on.
5.
If BATT-GEN gauge does not read in yellow or lower red, notify maintenance.
END OF WORK PACKAGE