CEP FIRE EXTINGUISHER LED(S) BLINK WHEN AFES IS POWERED
SYMPTOM
CEP fire extinguisher LED(s) blink when AFES is powered.
MALFUNCTION
Fire extinguisher has discharged or fault with discharge has occurred.
CORRECTIVE ACTION
NOTE
Blink sequences for fire extinguishers faults are different. A fail-to-flow fault will
have a noticeable pause while the discharge fault will not.
1.
Check if corresponding fire extinguisher bottle has discharged, as indicated by a steady blink
twice per second.
2.
Check if corresponding fire extinguisher bottle has fail-to-flow (no discharge occurred after
activation signal), as indicated by a repeated double blink followed by a pause.
3.
If extinguisher bottle has discharged or failed to discharge, notify maintenance.
CEP SENSOR FAULT LED(S) BLINK WHEN AFES IS POWERED
SYMPTOM
CEP sensor fault LED(s) blink when AFES is powered.
MALFUNCTION
CEP cannot communicate with one or more Optical Fire Sensor Assemblies (OFSA).
CORRECTIVE ACTION
1.
Check if OFSA lenses are clean and free from debris.
2.
If any lenses are dirty, clean with lens paper.
3.
Check for loose or disconnected wiring harness lead at corresponding OFSA.
4.
Reconnect any loose or disconnected harness leads.
5.
Press the CEP BIT/LAMP TEST switch to activate BIT test. If fault still exists,
notify maintenance.
TM 9-2350-256-10
0082
0082-3