TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 2 OF 4, CHAPTERS 5 THRU 9

  TM-9-2350-260-20-1-2 - Page 762 of 772

TM 9-2350-260-20-1-2
CENTRIFUGAL FAN HOUSING REPLACEMENT (Sheet 2 of 3)
2.
Remove fan housings (B) from powerplant.
3.
Using 1/2 inch socket, remove ten screws (C)
securing covers (D) to shroud (E).
4.
Remove covers (D) from powerplant.
5.
Using two 9/16 inch wrenches, remove two
screws, washers, and self-locking nuts (F) that
hold housing (G) and mount (H) together.
Throw
self-locking nuts away.
6.
Using 9/16 inch socket, remove four screws (J).
7.
Remove housing (G) and mount (H) from
powerplant.
INSTALLATION:
NOTE
Make sure no foreign matter is
present in fan housing.
1.
Position mount (A) and housing (B) onto
powerplant.
2.
Using two 9/16 inch wrenches, install two screws,
washers, and new self-locking nut (C) securing
mount (A) and housing (B) together.
3.
Using 9/16 inch socket, install four screws (D)
securing mount (A) and housing (B) to engine
shroud.
4.
Using feeler gage, check clearance between tip of
each fan blade and mount (A) and housing (B).
If
clearance is less than 0.062 inch, go to page 9-58,
step 17, for adjustment procedures.
Go on to Sheet 3
TA146906
9-60


Back to Top