TM 9-2350-260-20-1-3
INSTRUMENT PANEL CLUSTER ASSEMBLY REPAIR (Sheet 5 of 23)
Battery Generator Indicator Replacement (Sheet 2 of 2)
INSTALLATION:
1.
Apply silicone compound (Item 32, Appendix D) to indicator (A) electrical connector.
2.
Place indicator (A) in position in panel.
3.
Using wrench, install two nuts (C) and new lockwashers (D) securing indicator (A) and mounting bracket (B) on panel.
5.
Connect lead (circuit 27) to rear of indicator (A) by pushing in.
6.
Install instrument panel in tank (page 10-138).
End of Task
TA147176
10-144