TM 9-2350-260-20-1-3
INSTRUMENT PANEL CLUSTER ASSEMBLY REPAIR (Sheet 12 of 23)
Fuel Tank Liquid Quantity Indicator Replacement (Sheet 1 of 3)
TOOLS:
3/8 in.
combination box and open end wrench (2 required)
SUPPLIES:
Silicone compound (Item 32, Appendix D)
Lockwasher (MS35338-43) (2 required)
PRELIMINARY PROCEDURE:
Remove instrument panel from tank (page 10-136)
REMOVAL:
1.
Using one wrench on nut, flatwasher and lockwasher (A), and one wrench to hold stud (B) (hidden), remove nut,
flatwasher and lockwasher (A) securing harness junction (C) to panel.
2.
Displace harness junction (C).
3.
Disconnect two leads (circuits 27 and 28) from rear
of indicator (D).
4.
Using wrench, remove stud (B) and flat washer (G).
5.
Using wrench, remove two nut and lockwashers (E)
securing mounting bracket (F) to panel.
Throw
lockwashers away.
6.
Remove indicator (D) from panel.
Go on to Sheet 2
TA147183
10-151