TM 9-2350-260-20-1-3
INSTRUMENT PANEL CLUSTER ASSEMBLY REPAIR (Sheet 17 of 23)
Fuel Tank Selector Switch Replacement (Sheet 1 of 2)
TOOLS:
Flat-tip screwdriver
SUPPLIES:
Silicone compound (Item 32, Appendix D)
PRELIMINARY PROCEDURE:
Remove instrument panel from tank (page 10-136)
REMOVAL:
1.
Remove three leads (circuits 30, 28, and 31) from rear of switch (A) by pulling out.
2.
Using screwdriver, remove two assembled screws
(B) securing switch (A) to panel.
3.
Remove switch (A).
INSTALLATION:
1.
Apply silicone compound (Item 32, Appendix D) to
three switch (A) leads (circuits 30, 28, and 31).
2.
Place switch (A) in position in panel.
3.
Using screwdriver, install two assembled screws (B)
securing switch (A) to panel.
Go on to Sheet 2
TA147188
10-156