TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 177 of 783

TM 9-2350-260-20-1-3
BILGE PUMP STOWAGE RECEPTACLE PLATE REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
1.
Place shell (A) onto plate (B).
2.
Using screwdriver, install four screws (C) and new
lockwashers (D), securing shell (A) to plate (B).
3.
Place new lockwasher, ground cable (F), washer (G), and clamp (H) onto screw (J).
4.
Place plate (B) onto plate assembly (K).
5.
Install screw (J) with assembled items (E, F, G, and H) through plate (B) and plate assembly (K).
6.
Place new lockwasher (L) and nut (M) onto screw (J).
7.
Using 7/16 inch wrench to hold nut (M), use socket to tighten screw (J).
8.
Install connector (N) to shell (A).
End of Task
TA147197
10-165