TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 180 of 783

TM 9-2350-260-20-1-3
INFRARED RECEPTACLE STOWAGE ASSEMBLY REPLACEMENT (Sheet 1 of 1)
TOOLS:
Flat-tip screwdriver
SUPPLIES:
Lockwasher (M35338-41) (4 required)
BENEATH TACHOMETER
(LEFT SIDE)
NOTE
Be sure MASTER CONTROL switch is
OFF.
REMOVAL:
1.
Remove electrical connector (A).
2.
Using screwdriver, remove four screws (B) and
lockwashers (C).
Throw lockwashers (C) away.
3.
Remove receptacle (D).
INSTALLATION:
1.
Place receptacle (D) in position.
2.
Using screwdriver, install four screws (B) and new
lockwashers (C).
3.
Install electrical connector (A).
End of Task
TA147200
10-168


Back to Top