TM 9-2350-260-20-1-3
MASTER RELAY REPLACEMENT (Sheet 2 of 3)
REMOVAL:
1.
Using spanner wrench, remove connector (A) from master relay (B).
2.
Using spanner wrench, remove connector (C) from master relay (B).
3.
Using 7/8 inch wrench, remove connector (D).
NOTE
Some tanks do not have protection device (E).
If your tank does not have
protection device (E), skip step 4 and go on to steps 5 and 6.
If your tank does
have protection device (E), continue with steps 4 through 6.
4.
Using 3/4 inch wrench, remove protection device (E) from master relay (B).
5.
Using socket and 1/2 inch wrench, remove two bolts (F), four lockwashers (G), and two nuts (H).
Throw lockwashers
(G) away.
6.
Remove master relay (C) from plate (J) and from tank.
Go on to Sheet 3
TA147204