TM 9-2350-260-20-1-3
PROTECTION DEVICE REPLACEMENT (Sheet 2 of 3)
REMOVAL:
CAUTION
Make sure MASTER CONTROL switch is set to OFF before replacing protection
device.
1.
Using spanner wrench, loosen connector (A).
2.
Manually remove connector (A) from master relay
(B).
3.
Using 7/8 inch wrench, loosen connector (C).
4.
Manually remove connector (C) from protection
device (D).
5.
Using 3/4 inch wrench, remove protection device (D) from master relay (B).
Go on to Sheet 3
TA147207
10-175