TM 9-2350-260-20-1-3
AIR CLEANER BLOWER MOTOR RELAY REPLACEMENT (Sheet 2 of 2)
REMOVAL:
1.
Using spanner wrench, remove electrical connector (A) from air cleaner blower motor relay (B).
2.
Using socket, remove two screws (C) and lockwashers (D) holding air cleaner blower motor relay (B) to plate (E).
Throw lockwashers (D) away.
3.
Remove air cleaner blower motor relay (B) from tank.
INSTALLATION:
1.
Position air cleaner blower motor relay (B) in tank.
2.
Using socket, install two screws (C) and new lockwashers (D) to hold air cleaner blower motor relay (B) to plate (E).
3.
Using spanner wrench, install electrical connector (A) to air cleaner blower motor relay (B).
4.
Connect three battery ground straps (page 10-294).
End of Task
TA147216