TM 9-2350-260-20-1-3
FIRE EXTINGUISHER AND PERSONNEL HEATER CIRCUIT BREAKERS REPLACEMENT (Sheet 3 of 3)
INSTALLATION:
1.
Position fire extinguisher circuit breaker (A) and personnel heater circuit breaker (B) in tank.
2.
Using screwdriver, install two screws (C) and new lockwashers (D) to hold fire extinguisher circuit breaker (A) to plate
(E).
3.
Using screwdriver, install two screws (F) and new lockwashers (G) to hold personnel heater circuit breaker (B) to
plate.
4.
Connect two cable connectors (H) to fire extinguisher circuit breaker (A) and two cable connectors (J) to personnel
heater circuit breaker (B).
5.
Connect three battery ground straps (page 10-294).
End of Task
TA147219
10-187