TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 201 of 783

TM 9-2350-260-20-1-3
RELAY AND CIRCUIT BREAKER MOUNTING PLATE REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
1.
Position plate (A) into mounting place.
2.
Using 9/16 inch wrench, install two screws (B) at
rear end of plate (A).
3.
Using 9/16 inch wrench, tighten two screws (C) at
front end of plate (A).
4.
Install fire extinguisher relay (page 10-182).
5.
Install two circuit breakers (page 10-187).
6.
Install blower motor relay (page 10-184).
End of Task
TA147221
10-189


Back to Top