BILGE PUMP RELAY ENCLOSURE ASSEMBLY REPAIR (Sheet 7 of 12)
Cable Assembly Replacement (Sheet 4 of 4)
5.
Place lead 451B with flat washer and new
lockwasher onto terminal.
6.
Using 7/16 inch socket, install nut (F) to terminal A2.
7.
Place flat washer and lead 451 on terminal X1.
8.
Using 5/16 inch socket, install nut (G) with new
lockwasher.
9.
Place cover (H) and new gasket (J) onto enclosure
assembly (B).
10. Using cross-tip screwdriver, install four screws (K)
with new lockwashers (L).
11. Install
enclosure
assembly
(B)
in
tank
(page 10-191).
End of Task
TA147230