TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 219 of 783

TM 9-2350-260-20-1-3
INFRARED POWER SUPPLY AND SHOCK MOUNT ASSEMBLY REPLACEMENT
(Sheet 4 of 5)
INSTALLATION:
1.
Position mount (A) on outside of bracket (B).
Insert screw (C) through inside of bracket (B).
Install mount (A), washer
(D), and nut (E) onto screw (C).
2.
Using 1/4 inch wrench to hold nut (E), use
screwdriver to tighten screw (C).
3.
Repeat steps 1 and 2 to install remaining mounts (A)
into brackets (B).
4.
Position washer (F) on screw (G).
Install screw (G) through mount (A), washer (H), hole (J) in power supply (K),
washer (L), ground strap (M), washer (L), and washer (N).
Using 7/16 inch wrench to hold screw (G), use 7/16 inch
socket to tighten nut (P).
5.
Using same procedure described in step 4, except omitting washers (L) and ground strap (M) install Dower supply (K)
onto brackets (B).
Go on to Sheet 5
TA147239
10-207


Back to Top